Modern Prefab Cabins Technical Specifications

PREFAB CABINS TECHNICAL SPECIFICATIONS
PRODUCTION DIMENSIONS Can be produced in requested sizes
HEIGHT 2800 mm including parapet.
METAL PARTS ST 37
CEMENT BORAD TSE 634-2
GLASS WOOL TS 901
EPS TS EN 13163
TECHNICAL DATA
EARTHQUAKE CONDITIONS 1st degree
CLIMATE CONDITIONS 3rd Climate zone
SNOW LOAD VALUE 80 Kg/m²
WIND SPEED VALUE 80 Km/Hour(Must be fixed to the ground)
EXTERIOR WALL INSULATION COEFFICIENT K:0.50 Kcal/m2hc
ROOF INSULATION COEFFICIENT K:0.69 Kcal/m2hc
GROUND INSULATION COEFFICIENT K:0.68 Kcal/m2hc
CHASIS LOAD CAPACITY 200 Kg/m²
FLOOR
FLOOR COVER 2.5 mm thick PVC vinyl is used on 14 mm thick cement board
OUTER WALL
SYSTEM Outer surfaces are covered with wooden pattern or stone pattern cemet board of 12 mm thick upon request.
OUTER SURFACE COVERING Outer surfaces are covered with wooden pattern or stone pattern cemet board of 12 mm thick upon request.
INNER SURFACE COVERING 8 mm thickness cement board (For WC unıts , PVC is in used as inner surface covering.)
WALL INSULATION 40 mm thickness and 10 kg/m3 EPS with B1 fire class; Full insulation, safety and healthy materials.
INNER WALL
SYSTEM Specially shaped box section with galvanized steel frame
INNER SURFACE COVERING 8 mm thickness cement board (For WC products , PVC is in used as inner surface covering.)
WALL INSULATION 40 mm thickness and 10 kg/m3 EPS with B1 fire class; Full insulation, safety and healthy materials.
ROOF
ROOF SYSTEM Special shaped construction that is produced as single piece carrier profiles, fringed 20cm and 36cm height of the parapet. Rain water is discharged through corner beams.
ROOF INSULATION 80 mm thick glasswool (14 kg/m³)
INNER SURFACE COVERING For ceiling covering PVC is in use( optionally 8 mm cement board can be used)(For WC metropol cabins, inner surface covering is made of PVC)
OUTER SURFACE COVERING 0,50 mm thickness , 27mm * 200 mm joint gap unpainted Trapezoid galvanized metal sheet.
DOORS
EXTERNAL DOOR 90*210 cm with TSE certificate white coloured , PVC material.
INTERNAL DOOR 80*200 cm Wooden, American door.
WINDOWS
Window 120 *100 cm TSE certificate white coloured , PVC material.
Sill PVC is used on the window sill of the inside edge.
Glass 4+9+4 double glazing glass
PAINTING
EXTERIOR SURFACE Silicon-based painting is in used with requested colours.
DOOR FRAME 1 layer Rapid undercoat .
METAL PARTS 1 layer Rapid undercoat.
ELECTRICAL INSTALLATIONS
SYSTEM Each room has a switch, a socket and a phone socket.It is also used spot lighting fixtures in every four eaves corners.
CABLE Electric power 2000 W 220 volt.3x2,5 mm for sockets, for lighting 2x1,5 mm TSE certificated NYM cables are used.
LIGHTING TSE certificated fixtures are in used.
PLUGS AND SWITCHES TSE certificated materials are in used.
SANITARY INSTALLATION
SANITARY WARE TSE certificated materials are in used.
FRESH WATER PIPES PPRC pipes with TSE certified..
WASTE WATER PIPES PVC pipes with TSE certification
OUTER CONNECTIONS
Concrete base should be 20 cm wider from each side ,fixing the cabin to the ground, outer connections of electricity,fresh water and waste water are responsabilities of the customer.
LIFTING
Conteiners can be lifted with steel cables from lifting lugs from the corners.
Karmod Prefabricated Building Technologies has the right to make modifications in the Technical Specifications.
 